生物悬浮填料常规验收方法:
第一步: 选择一个方箱作为会计容器进行验收,其净大小为1m × 1m。相应类型的悬浮填料自然堆积在箱体内,填料自然堆积的平面与箱体上的平面平齐,即1m ³ 的填料,测得填料的实际重量为1m ³。1m ³ 填料实际重量在整个验收过程中随机取样,取样频率不得小于1%。
步骤2: 不同类型悬浮载体填料的有效比表面积不同,因此需要根据购买的总有效生物膜面积换算相应类型填料的总体积,计算悬浮填料的填充率。
步骤3: 计算所供应的填料类型的总体积 (m3) × 填料类型的实际重量 (kg/m3) 1m = 最终接受的填料重量 (kg)。
Filler acceptance method:
Step 1: Select a square box as the accounting container for acceptance, with a net size of 1m × 1m × 1m. The suspension filler of the corresponding type is naturally accumulated in the box body, and the plane where the filler is naturally accumulated is level with the plane on the box body, that is, 1m ³ of filler, and the actual weight of 1m ³ of filler is measured. The actual weight of 1m ³ filler shall be randomly sampled during the whole acceptance process, and the sampling frequency shall not be less than 1%.
Step 2: The effective specific surface area of different types of suspended carrier fillers is different, so it is necessary to convert the total volume of the corresponding type of filler according to the total effective biofilm area purchased, and calculate the filling rate of the suspended filler.
Step 3: Calculate the total volume (m3) of the supplied type of filler × the actual weight (kg/m3) of the type of filler 1m = the final accepted filler weight (kg).